Is this the Norris–Landzberg model?
No. This page intentionally uses the simpler Coffin–Manson temperature-range relation and does not include frequency or maximum-temperature terms.
Reliability Toolkit
Compare cycle severity using a simplified Coffin–Manson relationship based on temperature excursion and a user-selected fatigue exponent.
How to use it
Enter use and accelerated ΔT values.
Enter the justified fatigue exponent m.
Translate accelerated cycles to equivalent use cycles only within the model's applicability.
Questions
No. This page intentionally uses the simpler Coffin–Manson temperature-range relation and does not include frequency or maximum-temperature terms.
No. The exponent is an input because package, interconnect, material system and failure mode affect the appropriate fatigue relationship.